无码成人片一区二区三区免费,亚洲精品第一页,久久久久久夜夜夜猛噜噜,国产一级二级电影网站

  • 
    

    <b id="oiob6"><wbr id="oiob6"><ins id="oiob6"></ins></wbr></b>
  • <blockquote id="oiob6"></blockquote>
    1. <i id="oiob6"><sub id="oiob6"></sub></i>
      YANGJI Electrical
       
           PCB Solid State Relay
           Caliper Contactor Series
           Multi Loop Solid State Relay
           Single-phase Solid State Relay AC
           Single-phase Solid State Relay DC
           AC Voltage Regulation/DC Speed Regulation
           Industrial Modules
           Three-phase Solid State Relay AC/DC
           AC/DC Forward and Reverse Controller
           YANGJI Solid State Relay
           Solid State Relay AC For Export
           Voltage Regulating Modles/Power Controller
           Thyristor/Rectifiter/Hybrid Modules
           Electric Welding Machine Modules
           Single/Three Phase Rectifying Bridge Modules
           Solid State Radiator
           Temperature Controller
           Switch Power Supply
       
       
      Voltage Regulating Modles/Power Controller >> Three-phase cycle controller-(Power regulating module) MGL38AT

       

      Features:
      In industrial electric heating application system, there are three methods to adjust electric heating power
      1. Phase shift voltage regulation control;
      2. Duty cycle control;
      3. Cycle power regulation control;

      Applications:
      The module adopts SMT technology of imported components, accepts 1-5V, 4-20mA signal input, or 10K potentiometer direct manual control, generates the corresponding cycle zero crossing control signal output, drives the load, has small impact on the load, strong anti-interference and high reliability.
      It is used for temperature control of lighting equipment, oven and other heating equipment.


      Module selection and precautions:
      1. The selection of module current specification should take into account the fluctuation of grid voltage and instantaneous current impact when load starts, environmental conditions and heat dissipation conditions, in order to ensure the long-term reliable operation of the module, it is suggested that:
      Resistive load: the current capacity of the selection module is 3-4 times of the actual working current;
      Inductive load: the nominal current of the module should be 5-6 times of the actual current of the load;

      2. The module can't output large current for a long time (high input voltage, low output voltage). It may cause the module to burn out. It is suggested that the output voltage of the module should be adjusted above 1 / 2 of the input voltage.

      3. Over voltage and over-current protection: the output terminal of the module is connected in parallel with a varistor (voltage 800-900v), which can effectively protect the over-voltage. The main circuit is connected in series with a quick fuse or a circuit breaker as the over-current protection, and the £¦#118alue is 1.5 times of the actual current.

      4. The working calorific £¦#118alue of the module is calculated according to the actual current * 1.5; The radiator must be installed above 10A, forced air cooling or water cooling above 40A,  to facilitate the effective heat dissipation of the module, to prevent the module from burning electronic components or chip breakdown due to high temperature.



      Code£ºZ21G


        
       

      About Us

      Company Profile
      Company Culture
      Certificates

      Products

      PCB Solid State Relay
      Caliper Contactor Series
      Multi Loop Solid State Relay
      Single-phase Solid State Relay AC
      Single-phase Solid State Relay DC

      Customer Service

      Service
      Jion Us
      News and Events
      Sales Network
      Logisitics

      Contact

      Links

      Website
      ÖÐÎÄ°æ
      Alibaba